INSPECTING BURNERS
Check pilot ame pattern and burner ame pat-
terns often.

Figure 14 shows a correct pilot ame pattern.
Figure 15 shows an incorrect pilot ame pattern.
The incorrect pilot flame is not touching the
thermocouple. When the thermocouple cools, the
heater will shut down.
If pilot ame pattern is incorrect, as shown in
Figure 15
turn heater off (see To Turn Off Gas to Appli-
ance, page 12)
see Troubleshooting, page 15
Note: The pilot ame on natural gas units will
have a slight curve, but ame should be blue and
have no yellow or orange color.
Figure 15 - Incorrect Pilot Flame Pattern
(Your Pilot May Differ from Pilots Shown)
Figure 14 - Correct Pilot Flame Pattern
(Your Pilot May Differ from Pilots Shown)

Figure 16 shows correct burner ame pattern.





If burner ame pattern is incorrect, as shown in
Figure 17
turn appliance off (see To Turn Off Gas to Ap-
pliance, page 12
see Troubleshooting, page 15
Figure 16 - Correct Burner Flame Pattern
Figure 17 - Incorrect Burner Flame
Pattern
Pilot Burner
Thermocouple
Thermocouple
Pilot Burner
Thermocouple
Thermocouple
Yellow Flames
with Orange
Streaks
Dark Orange
Flames
Vista de pagina 12